Description: Abnormally low toner density detected black TCR sensor. When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
Remedy: 1. Perform image troubleshooting procedure if image density is low. 2. Reinstall developing unit/K. 3. Reinstall toner cartridge/K. 4. Check the connector between the developing unit/K-FRB CN13 for proper connection and correct as necessary. 5. Check the connector between FRB CN1, CN3-MFPB CN4E, CN11E for proper connection and correct as necessary. 6. M25 operation check • Control signal: MFPB CN30E-1 to 4 • Location of electrical component: 16-C 7. M6 operation check • Control signal: MFPB CN30E-5 to 8 • Location of electrical component: 17-C 8. If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 9. Replace the developing unit/K. 10. Replace FRB. 11. Replace MFPB.