Description: • C2563: Yellow TCR sensor failure • C2564: Black TCR sensor failure. Alarm signals for each TCR sensor is detected more than the predetermined number of times. This detection is used for detecting disconnection of TCR sensor connector.
Causes: • Developing unit/C,M,Y,K • Front side board (FRB) • MFP board (MFPB)
Remedy: 1. Reinstall developing unit. 2. Check the connector between the developing unit-FRB CN13 (C2564), CN14 (C2561), CN15 (C2562), CN16 (C2563) for proper connection and correct as necessary. 3. Check the connector between FRB CN1, CN3-MFPB CN4E, CN11E for proper connection and correct as necessary. 4. Replace the developing unit. 5. Replace FRB. 6. MFPB ICP2E conduction check 7. Replace MFPB.