Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C3922, C3925, C3926 — Konica-Minolta bizhub C658

Code: C3922, C3925, C3926

Description: • C3922: Fusing sensor wire breaks detection (Edge of the heating roller) • C3925: Fusing sensor wire breaks detection (Main of the heating roller) • C3926: Fusing sensor wire breaks detection (Center of the heating roller). • C3922: After a predetermined period of time after the warm-up stage is started, the heating roller thermistor/1 (TH1) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time. • C3925: After a predetermined period of time after the warm-up stage is started, the heating roller temperature sensor (TEMS) voltage does not increase by predetermined steps (temperature rise) within a predetermined period of time. • C3926: After a predetermined period of time after the warm-up stage is started, the heating roller thermistor/2 (TH2) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time.
Causes: • Fusing unit • C3922: Heating roller thermistor/1 (TH1) • C3925: Heating roller temperature sensor (TEMS) • C3926: Heating roller thermistor/2 (TH2) • MFP board (MFPB)
Remedy: 1. Check the fusing unit for correct installation (whether it is secured in position). 2. Check the open/close operation of the right door. 3. Check the fusing unit and MFPB for proper connection and correct or change as necessary. 4. Replace the fusing unit. 5. Replace MFPB.

← Xem tất cả mã lỗi Konica-Minolta bizhub C658

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie