Description: • C9401: Exposure LED lighting failure • C9402: Exposure LED lighting abnormally. • C9401: The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment. • C9402: The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.
Remedy: 1. Correct the harness connection between SCDB CN3-LU201 if faulty. 2. Check the connector between SCDB CN2-MFPB CN12E for proper connection and correct as necessary. 3. Check the connector between CCDB CN3-MFPB CN1 for proper connection and correct as necessary. 4. Check the status of the harness between CCDB-MFPB and replace as necessary. 5. Replace the LED exposure unit. 6. Replace CCDB. 7. Replace SCDB. 8. Replace MFPB.