Description: Tray 1 feeder up/down abnormality The tray 1 upper limit sensor (PS6) is not blocked even after the lapse of a given period of time after the lifting motion has been started
Causes: • Tray 1 upper limit sensor (PS6) • Tray 1 lift-up motor (M6) • Paper feed/transport drive board (PFTDB) • Printer control board (PRCB)
Remedy: 1 Check the connector between M6-PFTDB CN27 for proper connection and correct as necessary. 2 Check the connector of M6 for proper drive coupling and correct as necessary. 3 Check the connector between PS6-relay CN145- PFTDB CN15 for proper connection and correct as necessary. 4 PS6 I/O check, sensor check PFTDB CN15-3 (ON) 1-P 5 M6 operation check PFTDB CN27-10 to 11 2 to 3-X. 6 Replace M6. 7 Replace PFTDB. 8 PRCB ICP10 conduction check. 9 Replace PRCB.