Description: Punch motor’s drive malfunction <When FS-535+ZU-606 is installed> The punch motor (M604) is not turned OFF even after the set period of time has elapsed after it is turned ON.
Causes: • Punch motor (M604) • ZU control board (ZUCB)
Remedy: 1 Check the connector between M604-relay CN644- relay CN638-ZUCB CN11 for proper connection, and correct as necessary. 2 Check the connector of M604 for proper drive coupling, and correct as necessary. 3 M604 operation check ZUCB CN11-2 (DRV) ZU-606 7-C. 4 Replace M604. 5 ZUCB ICP10 conduction check. 6 Replace ZUCB.