Mã lỗi C2551 — Konica-Minolta bizhub C754

Code: C2551

Description: Abnormally low toner density detected cyan TCR sensor
When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper.
Causes: • Imaging unit /C • Imaging unit /M • Imaging unit /Y • Toner cartridge /C • Toner cartridge /M • Toner cartridge /Y • Toner empty sensor/C (RS/C) • Toner empty sensor/M (RS/M) • Toner empty sensor/Y (RS/Y) • Toner supply motor/Y (M9) • Toner supply motor/M (M10) • Toner supply motor/C (M11) • Toner cartridge motor /YM (M13) • Toner cartridge motor /CK (M14) • Printer control board (PRCB)
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Reinstall imaging unit. 3 Reinstall toner cartridge. 4 Check the motor connector for proper connection and correct as necessary. 5 Check the connector of M9, M10, M11, M13, M14 for proper drive coupling and correct as necessary. 6 M9, M10, M11 operation check (At this time, IU must be non-installation.) M9: PRCB CN3-1 to 4 M10: PRCB CN3-5 to 8 M11: PRCB CN3-9 to 12 23 to 24-C. 7 M13, M14 operation check M13: PRCB CN4-1 to 4 M14: PRCB CN4-5 to 8 3-K. 8 Replace M9, M10, M11, M13, M14. 9 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 10 Replace imaging unit. 11 PRCB ICP23 or ICP24 conduction check. 12 Replace PRCB.

← Xem tất cả mã lỗi Konica-Minolta bizhub C754

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie