Description: Magenta TCR sensor failure Alarm signals for a TCR sensor are detected more than the predetermined number of times. This detection is used for detecting disconnection of TCR sensor connector.
Causes: • Imaging unit /C • Imaging unit /M • Imaging unit /Y • Developing unit /K • PH relay board (PHRYB) • Printer control board (PRCB)
Remedy: 1 • Reinstall the imaging unit /C,/M, /Y • Reinstall the developing unit /K. 2 Check the harness from imaging unit /C, /M, /Y and developing unit /K to PRCB CN2, 3, 4, 5 for proper connection and correct as necessary. • CN2: Developing unit /K • CN3: Imaging unit /C • CN4, CN5: Imaging unit /M, Imaging unit /Y - - 3 • Replace the imaging unit. • Replace the developing unit /K. 4 PRCB ICP 17 conduction check. 5 Replace PHRYB. 6 Replace PRCB.