Mã lỗi C3B03 — Konica-Minolta bizhub C754

Code: C3B03

Description: IH malfunction (monitor)
• Though the IH heater is ON, this status cannot be detected mechanically. (IH heater operation failure) • Though the IH heater is OFF, mechanically, the ON status is detected. (Malfunction of IH heater operation)
Causes: • Fusing unit • IH coil unit • IH magnetic erasing board (IHMEB) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IH coil unit, IHPU, IHMEB, NF1 and PRCB for proper connection and correct or change as necessary. 4 Replace the fusing unit. 5 Replace the IH coil unit. 6 Replace IHPU. 7 Replace IHMEB. 8 PRCB ICP5 conduction check. 9 Replace PRCB. 10 Replace NF1.