Description: DC power supply cooling fan's failure to turn The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary.
Causes: • DC power supply cooling fan (FM9) • DC power supply (DCPU) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM9-relay CN333- PRCB CN38 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM9 operation check PRCB CN38-1 (DRIVE) PRCB CN38-3 (LOCK) 19-K. 4 Replace FM9. 5 PRCB ICP3 conduction check. 6 Replace DCPU. 7 Replace PRCB.