Description: Tray 3 feeder up/down abnormality The tray 3 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Causes: • Tray 3 upper limit sensor (PS22) • Tray 3 lift-up motor (M23) • Paper feed/transport drive board (PFTDB) • Printer control board (PRCB)
Remedy: 1 Check the connector between M23-PFTDB CN18 for proper connection, and correct as necessary. 2 Check the connector of M23 for proper drive coupling and correct as necessary. 3 Check the connectors between PS22-relay CN193- relay CN113B-PFTDB CN20 for proper connection, and correct as necessary. 4 PS22 I/O check, sensor check PFTDB CN20-6 (ON) 6-X. 5 M23 operation check PFTDB CN18-3 to 4 9-X. 6 Replace M23. 7 PFTDB ICP7 conduction check. 8 Replace PFTDB. 9 Replace PRCB.