Code: C1131

Description: 2nd stopper motor’s drive malfunction
<When FS-535+ZU-606 is installed> The 2nd stopper home sensor (PS604) is not turned ON even after the set period of time has elapsed after the 2nd stopper motor (M603) starts searching home position.
Causes: • 2nd folding stopper motor (M603) • 2nd folding stopper home sensor (PS604) • ZU control board (ZUCB)
Remedy: 1 Check the connector between M603-relay CN675- relay CN30-ZUCB CN15 for proper connection, and correct as necessary. 2 Check the connector of M603 for proper drive coupling, and correct as necessary. 3 Check the connectors between PS604-relay CN674- relay CN636-ZUCB CN4 for proper connection, and correct as necessary. 4 PS604 I/O check, sensor check ZUCB CN4-5 (ON) ZU-606 4 to 5-C. 5 M603 operation check ZUCB CN15-7 to 12 ZU-606 4-C. 6 Replace M603. 7 ZUCB ICP6 conduction check. 8 Replace ZUCB.