Code: C1144
Description: Stacker plate drive motor’s malfunction
<When FS-535 is installed> • The trailing edge stopper home sensor (PS22) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M19) is turned ON. • The trailing edge stopper standby sensor/1 (PS23) is not blocked or unblocked even after the set period of time has elapsed after trailing edge stopper motor (M19) is turned ON. • The trailing edge stopper standby sensor/2 (PS42) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M19) is turned ON.
<When FS-535 is installed> • The trailing edge stopper home sensor (PS22) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M19) is turned ON. • The trailing edge stopper standby sensor/1 (PS23) is not blocked or unblocked even after the set period of time has elapsed after trailing edge stopper motor (M19) is turned ON. • The trailing edge stopper standby sensor/2 (PS42) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M19) is turned ON.
Causes: <When FS-535 is installed> • Stacker plate drive motor (M17) • Stacker plate home sensor (PS11) • FS control board (FSCB)
Remedy: When FS-535 is installed: 1 Check the connector between M17-relay CN233-FSCB CN23 for proper connection, and correct as necessary. 2 Check the connector of M17 for proper drive coupling, and correct as necessary. 3 Check the connector between PS11-FSCB CN20 for proper connection, and correct as necessary. 4 PS11 I/O check, sensor check FSCB CN20-12 (ON) FS-535 12-D. 5 M17 operation check FSCB CN23-19 to 20 FS-535 13-L. 6 Replace M17. 7 FSCB ICP9 conduction check. 8 Replace FSCB.