Description: Center fold change motor’s malfunction <When FS-535+SD-512 is installed> The center fold change gate home sensor (PS11) is not blocked or unblocked even after the set period of time has elapsed while the center fold change motor (M8) is energized.
Causes: <When FS-535+SD-512 is installed> • Center fold change motor (M8) • Center fold change gate home sensor (PS11) • SD drive board (SDDB) • FS control board (FSCB)
Remedy: 1 Check the connector between M8-SDDB J8 for proper connection, and correct as necessary. 2 Check the connector of M8 for proper drive coupling, and correct as necessary. 3 Check the connector between PS11-SDDB J8 for proper connection, and correct as necessary. 4 PS11 I/O check, sensor check SDDB J8-10 (ON) SD-512 2-G. 5 M8 operation check SDDB J8-11 to 14 SD-512 2-F to G. 6 Replace M8. 7 Replace SDDB. 8 Replace FSCB.