Code: C2557
Description: Abnormally low toner density detected black TCR sensor
When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper
When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper
Causes: • Developing unit /K • Toner cartridge /K • Toner empty sensor/K (PZS/K) • Toner supply motor/K (M12) • Toner cartridge motor /CK (M14) • Printer control board (PRCB)
Remedy: 1 Perform image troubleshooting procedure if image density is low. 2 Check the connector between M12-relay CN258- PRCB CN3 for proper connection, and correct as necessary. 3 Check the connector between M14-relay CN321-relay CN428-PRCB CN4 for proper connection, and correct as necessary. 4 Check the connector of M12 and M14 for proper drive coupling and correct as necessary. 5 M12 operation check (At this time, IU must be non-installation.) PRCB CN3-13 to 16 24-C. 6 M14 operation check PRCB CN4-5 to 8 3-K. 7 Replace M12 and M14. 8 Reinstall developing unit /K. 9 Reinstall toner cartridge. 10 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them. 11 Replace the developing unit /K. 12 PRCB ICP23 or ICP24 conduction check. 13 Replace PRCB.