Code: C3101
Description: Fusing pressure roller separation failure
• The fusing pressure home sensor (PS55) is not turned OFF (retracted state) even after the set period of time after the fusing pressure roller retraction operation is started. • The fusing pressure home sensor (PS55) is not OFF (retracted state) when the fusing pressure roller retraction operation is completed. • The fusing pressure home sensor (PS55) is not turned ON (pressed state) after the set period of time after the fusing pressure roller pressure operation is started. • The fusing pressure home sensor (PS55) is not ON (pressed state) when the fusing pressure roller pressure operation is completed.
• The fusing pressure home sensor (PS55) is not turned OFF (retracted state) even after the set period of time after the fusing pressure roller retraction operation is started. • The fusing pressure home sensor (PS55) is not OFF (retracted state) when the fusing pressure roller retraction operation is completed. • The fusing pressure home sensor (PS55) is not turned ON (pressed state) after the set period of time after the fusing pressure roller pressure operation is started. • The fusing pressure home sensor (PS55) is not ON (pressed state) when the fusing pressure roller pressure operation is completed.
Causes: • Fusing pressure home sensor (PS55) • Fusing pressure motor (M29) • Printer control board (PRCB) • Fusing unit
Remedy: 1 Check the connector between M29-PRCB CN29 for proper connection and correct as necessary. 2 Check the connector of M29 for proper drive coupling and correct as necessary. 3 Check the connector between PS55-PRCB CN17 for proper connection and correct as necessary. 4 PS55 I/O check, sensor check. 5 M29 operation check PRCB CN29-1 to 4 8-H. 6 Replace M29. 7 Replace the fusing unit. 8 PFTDB ICP15 or ICP25 conduction check. 9 Replace PRCB.