Code: C6104
Description: Back side cleaning home sensor abnormality (initial)
• The back side cleaning home sensor (PS9) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation. • The back side cleaning home sensor (PS9) does not change from L to H even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.
• The back side cleaning home sensor (PS9) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation. • The back side cleaning home sensor (PS9) does not change from L to H even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.
Causes: • Back side cleaning home sensor (PS9) • Back side cleaning motor (M7) • DF control board (DFCB)
Remedy: 1 Check the connector between M7-relay CN119-DFCB CN6 for proper connection, and correct as necessary. 2 Check the connector of M7 for proper drive coupling, and correct as necessary. 3 PS9 I/O check, sensor check DFCB CN3-11 (ON) DF-702 6-C. 4 M7 operation check DFCB CN6-5 to 8 DF-702 7-C. 5 Replace M7. 6 DFCB ICP4 conduction check. 7 Replace DFCB.