Description: Lift up mechanism trouble (Upward movement) The lift up upper sensor (PS2) is not unblocked after a lapse of a given time after the lift-up motor (M5) moves up (is turned forward).
Causes: • Lift-up motor (M5) • Lift-up upper sensor (PS2) • DF control board (DFCB)
Remedy: 1 Check the connector between M5-DFCB CN11 for proper connection, and correct as necessary. 2 Check the connector of M5 for proper drive coupling, and correct as necessary. 3 Check the connector between PS2-DFCB CN5 for proper connection, and correct as necessary. 4 PS2 I/O check, sensor check DFCB CN5-3 (ON) DF-702 10-C. 5 M5 operation check DFCB CN11-4 to 7 DF-702 13-C. 6 Replace M5. 7 DFCB ICP13 conduction check. 8 Replace DFCB.