Description: Dynamic link error during starting (AP0) Dynamic link error during starting (AP1) Dynamic link error during starting (AP2) Dynamic link error during starting (AP3) Dynamic link error during starting (AP4) Dynamic link error during starting (LDR) Dynamic link error during starting (IBR) Dynamic link error during starting (IID) Dynamic link error during starting (IPF) Dynamic link error during starting (IMY) Dynamic link error during starting (SPF) Dynamic link error during starting (OAP). A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON.
Causes: MFP board (MFPB)
Remedy: 1 If the malfunction code "C-C172" has occurred, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if "Controller 2," "Controller 3," or "Others" is set for [Image Controller Setting]. If any of these is set, according to the kind of controller, select "Controller 0" or "Controller 1." - - 2 If the malfunction code "C-C180" has occurred, check to install the appropriate loadable driver for an authentication unit which is installed to the MFP. - - 3 Replace MFPB - - 4 When not reviving even if the above-mentioned procedure is done, contact the responsible people of KMBT.