Mã lỗi C0500 — Konica-Minolta bizhub C8022

Code: C0500

Description: Heating Roller warm-up failure
• The temperature of the Heating Roller does not reach 100 °C within 50 sec. after the Heating Roller Heater Lamp has been turned ON. • The temperature of the Heating Roller does not reach 100 °C and that of the Fusing Pressure Roller does not reach 195 °C within 200 sec. after the Heating Roller Heater Lamp has been turned ON. • The voltage of the Heating Roller Thermistor does not increase by five steps within 20 sec. after the Heating Roller Heater Lamp has been turned ON. • No zero cross signal is detected even with the lapse of 1 sec. or more after the Heating Roller Heater Lamp has been turned ON.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PWB-MC and PU1 for proper connection and correct or change as necessary. 3 Change Fusing Unit. 4 Change PWB-MC. 5 Change PU1.