Code: C-0205
Description: Tray2 up abnormality 1. When the upper limit sensor /2 (PS10) is OFF, PS10 does not turn ON within 20 seconds after the tray lift-up motor /2 (M34) turns ON for lifting operation. At this time, an error detection signal (24V cut off) is detected.
Causes: • Upper limit sensor /2 (PS10) • Tray lift-up motor /2 (M34) • Printer control board (PRCB) • DC power supply /2 (DCPS/2) DIPSW18-1
Remedy: 1. Check the paper loaded condition and the rear end restriction plate condition of the tray2, and repair it if any abnormality 2. Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 21-A) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: Main body (2/4): 18-A) 5. Replace PS10. 6. Replace M34 7. Replace PRCB. 8. Replace DCPS /2