Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C-0252 — Konica-Minolta bizhub PRESS 1052

Code: C-0252

Description: PI-PFU (PF-703) middle tray up abnormality. When the upper limit sensor /2 (PS9) is OFF, PS9 does not turn ON within 20 seconds after the paper lift motor /2 (M8) turns ON for lifting operation. Or, the paper suction sensor /Fr2 and / Rr2 (PS27 and PS28) turn ON before PS9 turns ON while in tray lifting.
Causes: • Upper limit sensor /2 (PS9: PF-703) • Paper lift motor /2 (M8: PF-703) • PF drive board (PFUDB: PF-703) DIPSW37-0
Remedy: 1. Check the paper loaded condition and the rear end restriction plate misaligned of the middle tray, and repair it if any abnormality 2. Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality (Wiring diagram: PF-703: 12-F) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: PF-703: 9-F) 5. Replace PS9: PF-703 6. Replace M8: PF-703 7. Replace PFUDB.

← Xem tất cả mã lỗi Konica-Minolta bizhub PRESS 1052

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie