Code: C-0312
Description: Paper exit cooling fan /Lw2 (FM28) rotation abnormality. The FM28 EM error detection signal is detected twice in succession within a specified period of time after FM28 was turned ON. However, error detection signal (24V cut off) is not detected.
Causes: • Paper exit cooling fan / Lw2 (FM28) • Printer control board (PRCB) • AC drive board (ACDB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between ACDB and the fan, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: Main body (2/4): 9-A) 4. Replace FM28. 5. Replace PRCB. 6. Replace ACDB.