Mã lỗi C-0389 — Konica-Minolta bizhub PRESS 1052

Code: C-0389

Description: PI-PFU (PF-703) paper feed assist fan /Fr2 (FM5) power abnormality. The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper feed assist fan / Fr2 (FM5: PF-703) • Paper feed assist fan / Fr2 (FM3: PF-706 ) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 10-F, PF-706: 7-C) 3. Replace FM5 and PFUDB at a time: PF-703 Replace FM3 and PFUDB at a time: PF-706