Code: C-0581
Description: PI-PFU (PF-703) paper suction fan /3 (FM16) power abnormality. The FM16 EM error detection of FM16 is detected twice in succession within a specified period of time after FM16 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Paper suction fan /4 (FM16: PF-703) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 16-L) 3. Replace FM16 and PFUDB.