Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C-1125 — Konica-Minolta bizhub PRESS 1052

Code: C-1125

Description: The tray upper limit sensor /Up (PS205) or the tray lower limit sensor /Up (PS204) does not turn ON within a specified period of time after the tray up down motor /Up (M201) turns ON.
Causes: • FNS control board (FNSCB) • PI drive board (PIDB) • Tray up down motor /Up (M201) • Tray upper limit sensor / Up (PS205) • Tray lower limit sensor / Up (PS204) DIPSW47-3
Remedy: 1. Check the PI lower tray section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PIDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between FNSCB and PIDB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PI: 4-B) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: PI: 4-B) 6. Replace M201. 7. Replace PS204. 8. Replace PS205. 9. Replace PIDB. 10. Replace FNSCB.

← Xem tất cả mã lỗi Konica-Minolta bizhub PRESS 1052