Code: C-1223
Description: The 3rd folding cam home sensor (PS57) does not turn ON within a specified period of time after the 3rd folding release motor (M16) turns ON.
Causes: • 3rd folding release motor (M16) • Folding drive board (FDB) • 3rd folding cam home sensor (PS57) DIPSW6-0
Remedy: 1. Check the 3rd folding section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between FDB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FD-503: 1-B) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FD-503: 2-B) 5. Replace PS57. 6. Replace M16. 7. Replace FDB.