Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C-1230 — Konica-Minolta bizhub PRESS 1052

Code: C-1230

Description: After the FD paper lift motor /Up (M8) is in the down operation, the PI lift plate home sensor /Up (PS34) does not turn ON within a specified period of time. Or, after the paper lift motor /Up (M8) is in the up operation, the PI tray upper limit sensor /Up (PS32) does not turn ON.
Causes: • Paper lift motor /Up (M8) • PI drive board (PIDB) • PI lift plate home sensor /Up (PS34) • PI upper limit sensor /Up (PS32) DIPSW6-2
Remedy: 1. Check the PI upper tray section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PIDB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:FD-503:9-A) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram:FD-503:8-A, 9-A) 5. Replace PS32 or PS34. 6. Replace M8. 7. Replace PIDB.