Code: C-1246
Description: The bundle clip upper limit sensor (PS33) does not turn ON within a specified period of time after the bundle clip motor (M11) starts the home position search operation. Or, even after a specified period of time after M11 starts the operation, it does not stop.
Causes: • Bundle clip motor (M11) • Bundle clip upper limit sensor (PS33) • Bundle clip lower limit sensor (PS30) • SD control board (SDCB) • SD drive board (SDDB) DIPSW7-0
Remedy: 1. Check the bundle clip section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:SD-506:16-D) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram:SD-506:19-D) 6. Replace PS33. 7. Replace M11. 8. Replace SDDB. 9. Replace SDCB.