Code: C-2101
Description: Charger cleaning motor (M23) operation time abnormality.
Causes: • Charger cleaning limit sensor (PS26) • Charger cleaning limit sensor (PS27) • Charger cleaning motor (M23) • Web motor (M24) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (3/4): 16-I, 3-A) 3. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: Main body (3/4): 16-I, 17-I) 4. Replace PS26 or PS27. 5. Replace M23 or M24. 6. Replace PRCB.