Code: C-2318
Description: Charger exhaust fan (FM44) rotation abnormality. The FM44 EM error detection signal is detected twice in succession within a specified period of time after FM44 was turned ON. However, error detection signal (24V cut off) is not detected.
Causes: • Charger exhaust fan (FM44) • Printer control board (PRCB) • AC drive board (ACDB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between ACDB and the fan, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: Main body (2/4): 13-A) 4. Replace FM44. 5. Replace PRCB. 6. Replace ACDB.