Code: C-2803
Description: The IDC sensor (TCB) output abnormality. While in the maximum density correction (Dmax), a patch for control is not output. (No output is made from the gamma sensor.)
Causes: • Toner control board (TCB) • LPH board (LPHB) • Overall control board (OACB) • Image processing board (IPB)
Remedy: 1. Check TCB, and clean it with alcohol if there is IDC sensor dirt or any abnormality. (Wiring diagram: Main body (3/4): 18-I) Be sure to clean TCB with alcohol, otherwise replacement of TCB is required. 2. Check the LPH section, and clean/repair it if any dirt or abnormality. (Wiring diagram: Main body (4/4): 17-A) 3. Check the connector connection and the wiring between OACB and IPB, and repair it if any abnormality. 4. Check the connector connection and the wiring between LPHB and IPB, and repair it if any abnormality. 5. Replace LPHB. 6. Replace IPB. 7. Replace OACB.