Code: C-6719
Description: The original skew adjustment is too late. The scan operation starts before the original skew adjustment is terminated.
Causes: • Original skew sensor /Fr (PS312: DF-615/616) • Original skew sensor /Rr (PS311: DF-615/616) • DF control board (DFCB: DF-615/616) • Overall control board (OACB: main body)
Remedy: 1. Check the original skew sensor, and repair it if any abnormality. (Wiring diagram: DF-615/616: 2-E, 1-E) 2. Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between DFCB and OACB, and repair it if any abnormality. 4. Conduct the DF paper skew adjustment of the mechanical adjustment to correct the original skew. 5. Conduct [Service mode]-[Process adjustment]-[ADF Skew Offset Adj.] 6. Replace PS311 or PS312. 7. Replace DFCB 8. Replace OACB.