Code: C-0111
Description: Abnormality of the duplex section motor IC in the ADU drive board (ADUDB). The error detection signals of the ADU reverse motor (M12), the reverse/exit motor (M13), the ADU accelerate motor (M14) and the ADU conveyance motor /1 (M15) are detected after the print is started.
Causes: • ADU reverse motor (M12) • Reverse/exit motor (M13) • ADU acceleration motor (M14) • ADU conveyance motor /1 (M15) • ADU drive board /1 (ADUDB1)
Remedy: 1. Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, repair/replace it if any abnormality, and then replace M12, M13, M14, M15 (Wiring diagram: Main body (2/4): 19-P, 18-P, 7-P) 3. Replace ADUDB1 4. Replace M12, M13, M14, M15 and ADUDB1 at a time