Code: C-0266
Description: 1st tandem PF-703 shutter motor /3 (M12) operation time abnormality 2. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • Shutter motor /3 (M12: PF-703) • PF drive board (PFUDB: PF-703) DIPSW20-4
Remedy: 1. Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality (Wiring diagram: PF-703: 19-L) 3. Replace M12 and PFUDB at a time.