Code: C-0382
Description: 2nd tandem PF-703/706 cooling fan power abnormality. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected. PF-706: The FM7 EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • PF cooling fan /1 (FM19: PF-703) • PF cooling fan (FM7: PF-706 ) • PF cooling fan /2 (FM20: PF-703) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 22-F, 23-F, PF-706: 8-H) 3. Replace FM19, FM20 and PFUDB at a time: PF-703 Replace FM7 and PFUDB at a time: PF-706