Code: C-1202
Description: The shift unit home sensor (PS11) does not turn ON within a specified period of time after the shift unit motor (M5) turns ON. Or, PS11 does not turn ON within a specified period of time.
Causes: • Shift unit motor (M5) • LS control board (LSCB) DIPSW6-6
Remedy: 1. Check the shift unit section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 6-A) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 5-H) 5. Replace PS11. 6. Replace M5. 7. Replace LSCB.