Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C-1516 — Konica-Minolta bizhub PRESS 1250

Code: C-1516

Description: A rotation error detection signal is detected for a specified period of time in succession while the glue apply roller motor (M32) is driving.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Glue apply roller motor (M32) DIPSW7-6
Remedy: 1. Check the glue apply section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503:9-D) 5. Replace M32. 6. Replace PBDB1. 7. Replace PBCB.