Mã lỗi C-2702 — Konica-Minolta bizhub PRESS 1250

Code: C-2702

Description: A transfer leak is detected. After a transfer EM signal abnormality is detected while in the charge ON, up to 5 transfer ON/OFF operations occur in succession while in 10 prints.
Causes: • Transfer roller • High voltage unit /2 (HV2)
Remedy: 1. Check the transfer roller section, and clean/repair it if there is sensor dirt or any abnormality. 2. Clean the power feed section for the transfer roller. 3. Check the transfer roller pressure section, and clean/repair it if there is sensor dirt or any abnormality. 4. Check the connector connection and the wiring between HV2 and the power feed section, and repair/replace it if any abnormality. (Wiring diagram: Main body (2/4): 3-N) 5. Replace HV2.