Code: C-6303
Description: Scanner cooling fan (FM19) rotation abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, an error detection signal (blowout of a fuse/24V cut off) is not detected.
Causes: • Scanner cooling fan (FM19) • Scanner drive board (SDB) • Printer control board (PRCB)
Remedy: 1. Check the connector connection and the wiring between SDB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between SDB and PRCB, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: Main body (4/4): 15-K) 4. Replace FM19. 5. Replace SDB. 6. Replace PRCB.