Code: C-6721
Description: AGC retry. The AGC is retried due to the decreased light volume of the exposure lamp. However, no error occurs.
Causes: • Exposure lamp (L4) • L4 inverter (L4_INVB) • Scanner drive board (SDB) • CCD board (CCDB)
Remedy: 1. Check the reading section, and repair it if any abnormality such as cover off. 2. Check the connector connection and the wiring between IPB and CCDB, and repair it if any abnormality. 3. Check the connector connections and the wirings between SDB and L4_INVB, and L15_INVB and L16, and repair it if any abnormality. (Wiring diagram: Main body (4/4): 15-M, 16-J, 17-J) 4. When L4 is high-light intensity, low-light intensity or does not light, replace L4. 5. When L4 is high-light intensity, low-light intensity or does not light after replacing L4, replace L4_INVB. 6. Replace CCDB.