Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C-0359 — Konica-Minolta bizhub PRESS 1250p

Code: C-0359

Description: 1st tandem PF-703/706 cooling fan power abnormality. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected. PF-706: The FM7 EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: • PF cooling fan /1 (FM19: PF-703) • PF cooling fan (FM7: PF-706 ) • PF cooling fan /2 (FM20: PF-703) • PF drive board (PFUDB)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan by I/O or hand, and repair it if any abnormality. (Wiring diagram: PF-703: 22-F, 23-F, PF-706: 8-H) 3. Replace FM7 and PFUDB at a time: PF-706

← Xem tất cả mã lỗi Konica-Minolta bizhub PRESS 1250p

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie