Code: C-0412
Description: ADU drive board (ADUDB) power abnormality 2. An error detection signal (blowout of ICP) of the transfer paper correction sensor (PS4), transfer exposure lamp (L4) or SD is detected. However, an error detection signal (24V cut off) is not detected.
Causes: • ADU lock solenoid (SD6) • Reverse/exit solenoid (SD7) • De-curler solenoid /Up (SD8) • De-curler solenoid /Lw (SD5) • Centering sensor(PS4) • ADU drive board /1 (ADUDB1)
Remedy: 1. Check the connector connection and the wiring on ADUDB1, and repair it if any abnormality. 2. Check the connector connection and the wiring between ADUDB1 and sensor/solenoid/TSL, and repair it if any abnormality. (Wiring diagram: Main body (2/4): 13-J, 11-P, 12-P, 14-J). 3. Check the drive and the coupling of the sensor and the solenoid, and repair it if any abnormality. 4. Replace ADUDB1.