Code: C-0615
Description: 2nd tandem PF-703 dehumidifier fan /Rt3 (FM26) rotation abnormality. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Dehumidifier fan /Rt3 (FM26: HT-505) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 11-D) 3. Replace the fan heater (FM26). 4. Replace PFUDB.