Code: C-0654
Description: 2nd tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects the heater temperature exceeding 105°C.
Causes: • Upper tray fan heater (HT-505) • AC drive board /2 (ACDB/2: HT-505) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality. 2. Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. 3. Check the temperature and the installation of the fan heater, and repair it if any abnormality. 4. Replace the fan heater. 5. Replace ACDB/2. 6. Replace PFUDB.