Code: C-1102
Description: The tray up down motor (M11) does not turn OFF even when a specified period of time elapses after it starts operations. Or, it operates for more than the allowed time at a speed out of the specified one.
Causes: • FNS control board (FNSCB) • Main tray up down motor (M11) • Main tray upper limit sensor (PS14) DIPSW35-1
Remedy: 1. Check the tray up/down section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 3. Check the sensor operation, LED emission and light-receiving path, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 7-B) 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 7-B) 5. Replace LED1 and PS14. 6. Replace M11. 7. Replace FNSCB.