Code: C-1115
Description: The 1st folding knife home sensor (PS110) does not turn ON within a specified period of time after the1st folding knife motor (M107) turns ON.
Causes: • FNS control board (FNSCB) • SD control board (SDCB) • 1st folding knife motor (M107) • 1st folding knife home sensor (PS110) DIPSW47-2
Remedy: 1. Check the half-fold/fold&staple/tri-fold section, and repair it if any abnormality 2. Check the connector connection and the wiring between FNSCB and SDCB, and repair it if any abnormality. 3. Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 8-B) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 9-B) 6. Replace PS110. 7. Replace M107. 8. Replace SDCB. 9. Replace FNSCB.