Code: C-1124
Description: The tray upper limit sensor /Lw (PS209) or the tray lower limit sensor /Lw (PS210) does not turn ON within a specified period of time after the tray lift motor /Lw (M202) turns ON.
Causes: • FNS control board (FNSCB) • PI drive board (PIDB) • Tray lift motor /Lw (M202) • Tray upper limit sensor / Lw (PS209) • Tray lower limit sensor / Lw (PS210) DIPSW47-3
Remedy: 1. Check the PI lower tray section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PIDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between FNSCB and PIDB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PI: 5-B) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: PI: 6-B) 6. Replace M202. 7. Replace PS209. 8. Replace PS210. 9. Replace PIDB. 10. Replace FNSCB.