Code: C-1204
Description: The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) turns ON.
Causes: Grip conveyance motor (M4) DIPSW6-6
Remedy: 1. Check the grip conveyance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 6-A) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: LS-505: 2-H) 5. Replace PS5. 6. Replace M4. 7. Replace LSCB.