Mã lỗi C-1242 — Konica-Minolta bizhub PRESS 1250p

Code: C-1242

Description: The folding main scan alignment home sensor / Fr1 (PS18) does not turn ON within a specified period of time after the folding main scan alignment motor /Fr (M7) starts the home position search operation. Or, even after a specified period of time after M7 starts the operation, it does not stop.
Causes: • Folding main scan alignment motor /Fr (M7) • Folding main scan alignment home sensor / Fr1 (PS18) • SD control board (SDCB) • SD drive board (SDDB) DIPSW7-0
Remedy: 1. Check the folding main scan alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-506: 8-D) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-506: 13-D) 6. Replace PS18. 7. Replace M7. 8. Replace SDDB. 9. Replace SDCB.